hot water heat zone valve problems
card image

heating zone stays hot even when the thermostat isn

we're trying to solve a very strange hot water heating problem (drawing below). We just separated the the 2nd and 3rd floors in my house into two separate heating zones, and the 3rd floor is now staying at 75 even though its thermostat is set for 65 and isn't calling for heat.

qianxin@zozen.com > Get A Quote >

How to trouble shoot zone valve problem — Heating He

2 zone hot water system with baseboards ,first floor zone will demand heat but system doesn't respond. If I go down and hit the zone valve,the system fires up and all's well. I measured voltage on the 24v DC zone valve,it's OK.

qianxin@zozen.com > Get A Quote >

Central heating problems - faulty zone valves - Charlie DIY

Mar 12, 2016· Thirdly, whilst the Drayton zone valves had to be positioned with the flow direction in through ‘Port A’ and out through ‘Port B’ – which basically meant the hot water zone valve was upside down and the heating zone valve the right way up, it’s not critical which direction the Honeywell zone valves are positioned.

qianxin@zozen.com > Get A Quote >

How to Troubleshoot a Honeywell Zone Valve | Hunk

Author: You can Fix It!!!! Jul 17, 2017· Honeywell zone valves offer the flexibility to regulate temperature in different parts of your home. A thermostat mounted in each desired location controls a specific Honeywell zone valve. When the thermostat calls for heat, the zone valves opens and turns on the water circulating pump to allow water flow to the area.

qianxin@zozen.com > Get A Quote >

How to Troubleshoot a Malfunctioning Heating Zo

Aug 05, 2016· Investigate the Zone Valve. Hot water is moved through the baseboards of your heating system when your thermostats call for heat in each heating zone. To keep hot water from constantly moving through the radiators, valves close off the water pipes when the area is warm enough.

qianxin@zozen.com > Get A Quote >

How to Check if a Taco Zone Valve Head Is Working? | Hunk

Jul 17, 2017· Wait a few minutes then go back to the Taco valve. Place your hand on the top of the Taco valve unit. If it is warm or hot to the touch the valve is functioning. If it is cold or room temperature the valve is not functioning. The heat indicates the wax piece inside if heating up and thus expanding to push the water flow valve open.

qianxin@zozen.com > Get A Quote >

Troubleshooting Hot Water Zone Valves - ACHR Ne

Jan 26, 2001· Troubleshooting Hot Water Zone Valves 1. Check for 24 V at TR terminals. 2. With the thermostat calling, you should not read 24 V at TH terminals. 3. When power is applied, the motor should open the zone valve. 4. If the zone opens but the relay does not pull in, jump out the end switch on the

qianxin@zozen.com > Get A Quote >

Troubleshooting a Gas-Fired Hot Water Boiler

Author: Bob Formisano

Heating System Boiler Check Valves, Flow Control Valv

Author: Bob Formisano WINTER position on the flow control valve - is the position you want. In this position, if the valve is working as designed, it will prevent hot water from circulating through this zone by convection - that is when a circulator is not running and presumably when a themostat is NOT calling for heat,

qianxin@zozen.com > Get A Quote >

Honeywell Motorised Valves — Problems and Fault-findi

If both heating and hot water valves are closed when this happens, the heated water from the boiler will pass through a bypass, if one is fitted, before going back to the boiler. If no bypass is fitted the boiler may kettle violently, with loud bumping and banging noises as the heat can’t be dissipated, and it may to go overheat lockout.

qianxin@zozen.com > Get A Quote >

heating zone valve problem - YouTube

Click to view on Bi

Click to view on Bing14:21Mar 22, 2015· Description zone valve fault finding / troubleshooting and how they work. Heating problems? Radiators Coming On With Your Hot Water (Even With The Heating Off)?

qianxin@zozen.com > Get A Quote >

Zone Valve Problems: Know What to Look For | eLoc

Explanation of Zone Valves on Heating Boilers - Controlling Hot Water HeatOur photo at left shows a Honeywell (TM) zone valve installation.Heating water piping in a building, particularly where hot water baseboard heat isZone Valve Defects Checklist1. Zone valve does not work - jammed, stuck, does not open in response to call for heat at that zone. Provided the wiring and thermostat are correcBanging Heating Zone Valve: Backwards Zone ValvesWater hammer, discussed in general at WATER HAMMER NOISE DIAGNOSE & CURE, can occur in both building potable water supply systems (sinks, tubs, sho5 Simple Zone Valve Diagnostic Steps1. Mechanically-stuck zone valve motors. If your zone valve has a manual override lever you can test the valve to see if it will open and shut. (OuBoiler Component & Heating Zone Valve Life Affected by Boiler Water ChemistryWatch out: for boiler water chemical conditions that could contribute to zone valve failure. These include highly-corrosive water, improper pH, andZone Valves on Indirect-Fired Domestic Hot Water HeatersIndirect fired hot water heaters, in some designs, use a heating coil located in the bottom of the hot water tank to heat the domestic hot water (uHeating Zone Valves: Normally-Closed vs Normally-Open Designs & ApplicationsDennis B. Hoff said: (2/3/3014)We have a hot water boiler with 7 normally open Honeywell zone valves. They are mounted on the hot side of the boileAsk A Question Or Search InspectAPediaUse the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you Mar 02, 2010· The zone valve opens and closes according to the temperature in the room as determined by the thermostat and your settings. Sometimes the zone valve will fail to operate properly. This can be caused by a malfunctioning part on the valve itself or by a faulty thermostat or a faulty connection between the two.

qianxin@zozen.com > Get A Quote >